Master SCBA Air Consumption & Working Duration Calculator

Calculate remaining working minutes based on cylinder pressure (2216, 4500, or 5500 PSI / 200–300 Bar), cylinder rated volume, and personal air consumption rate (LPM).

🚨 Active Fireground Emergency For active structural fires or life hazards, dial immediate emergency dispatch Call: 911 / 112

🀿 SCBA Air Consumption & Turnaround Point Calculator

NFPA 1404 ROAM
Estimated Working Time 28.0 min
Turnaround Point (33% ROAM) Begin Egress at 2,800 PSI
EOSTI Low-Air Alarm (33%) Vibrates at 1,485 PSI

The NFPA 1404 Rule of Air Management (ROAM)

Under NFPA 1404, fire departments must mandate that firefighters exit hazardous IDLH (Immediately Dangerous to Life or Health) atmospheres before their low-air alarm activates. The End-of-Service-Time-Indicator (EOSTI) alarm is a life-safety emergency reserveβ€”not an invitation to begin exiting.

The Rule of Thirds

  • One-Third (33%): Dedicated to interior navigation, advance, search, and fire suppression.
  • One-Third (33%): Reserved for tactical egress and exiting the structure along the hose line.
  • One-Third (33%): Untouchable safety reserve for disorientation, entanglement, or MAYDAY rescue.